2D-shear wave elastography: number of acquisitions can be reduced according to clinical setting

Collaborators, Affiliations

VSports在线直播 - 2D-shear wave elastography: number of acquisitions can be reduced according to clinical setting

Marco Dioguardi Burgio et al. Insights Imaging. .

Abstract

Background: The factors affecting intra-operator variability of two-dimensional shear wave elastography (2D-SWE) have not been clearly established VSports手机版. We evaluated 2D-SWE variability according to the number of measurements, clinical and laboratory features, and liver stiffness measurements (LSM). .

Methods: At least three LSM were performed in 452 patients who underwent LSM by 2D-SWE (supersonic shear imaging) out of an initial database of 1650 patients. The mean value of the three LSM was our best measurement method. Bland-Altman plots were used to evaluate intra-operator variability when considering only one, or the first two measurements. Variability was assessed by taking the absolute value of the difference between the first LSM and the mean of the three LSM. Logistic regression was used to assess the factors associated with the highest tertile of variability V体育安卓版. .

Results: The limit of agreement was narrower with the mean of the first and second measurements than with each measurement taken separately (- 2. 83 to 2. 99 kPa vs. - 5. 86 to 6. 21 kPa and - 5. 77 to 5. 73 kPa for the first and second measurement, respectively). A BMI ≥ 25 kg/m2 and a first LSM by 2D-SWE ≥ 7. 1 kPa increased the odds of higher variability by 3. 4 and 3 V体育ios版. 9, respectively. Adding a second LSM didn't change the variability in patients with BMI < 25 and a first LSM by 2D-SWE < 7. 1 kPa. .

Conclusions: Intra-operator variability of LSM by 2D-SWE increases with both a high BMI and high LSM value. In patients with BMI < 25 kg/m2 and a first LSM < 7. 1 kPa we recommend performing only one LSM. VSports最新版本.

Keywords: Elasticity imaging techniques; Observer variation; Ultrasonography. V体育平台登录.

PubMed Disclaimer

Conflict of interest statement

The authors declare that they have no competing interests.

Figures

Fig. 1
Fig. 1
Study flowchart. 2D- SWE: two-dimensional shear wave elastography
Fig. 2
Fig. 2
Bland–Altman and regression plots for the first liver stiffness measurement (LSM) (a), second LSM (b) and mean of first and second LSM (c) versus the average of the 3 consecutive LSM
Fig. 3
Fig. 3
Variability of the first (a) liver stiffness measurement (LSM) and of the mean of the first and second (b) LSM according to body mass index (BMI) and the value of liver stiffness obtained by the first measurement using two-dimensional shear wave elastography

References

    1. Thampanitchawong P, Piratvisuth T. Liver biopsy: complications and risk factors. World J Gastroenterol. 1999;5:301–304. doi: 10.3748/wjg.v5.i4.301. - VSports - DOI - PMC - PubMed
    1. Regev A, Berho M, Jeffers LJ, et al. Sampling error and intraobserver variation in liver biopsy in patients with chronic HCV infection. Am J Gastroenterol. 2002;97:2614–2618. doi: 10.1111/j.1572-0241.2002.06038.x. - DOI - PubMed
    1. Ratziu V, Charlotte F, Heurtier A, et al. Sampling variability of liver biopsy in nonalcoholic fatty liver disease. Gastroenterology. 2005;128:1898–1906. doi: 10.1053/j.gastro.2005.03.084. - DOI - PubMed
    1. Castera L, Forns X, Alberti A. Non-invasive evaluation of liver fibrosis using transient elastography. J Hepatol. 2008;48:835–847. doi: 10.1016/j.jhep.2008.02.008. - DOI - PubMed
    1. Sigrist RMS, Liau J, Kaffas AE, Chammas MC, Willmann JK. Ultrasound elastography: review of techniques and clinical applications. Theranostics. 2017;7:1303–1329. doi: 10.7150/thno.18650. - DOI - PMC - PubMed