Randomized Controlled Trial
. 2016 Sep 29;375(13):1221-30.
doi: 10.1056/NEJMoa1608029. Epub 2016 Aug 27.

"V体育ios版" Defibrillator Implantation in Patients with Nonischemic Systolic Heart Failure

Collaborators, Affiliations
Free article
Randomized Controlled Trial

Defibrillator Implantation in Patients with Nonischemic Systolic Heart Failure

"V体育ios版" Lars Køber et al. N Engl J Med. .
Free article

Abstract

Background: The benefit of an implantable cardioverter-defibrillator (ICD) in patients with symptomatic systolic heart failure caused by coronary artery disease has been well documented VSports手机版. However, the evidence for a benefit of prophylactic ICDs in patients with systolic heart failure that is not due to coronary artery disease has been based primarily on subgroup analyses. The management of heart failure has improved since the landmark ICD trials, and many patients now receive cardiac resynchronization therapy (CRT). .

Methods: In a randomized, controlled trial, 556 patients with symptomatic systolic heart failure (left ventricular ejection fraction, ≤35%) not caused by coronary artery disease were assigned to receive an ICD, and 560 patients were assigned to receive usual clinical care (control group). In both groups, 58% of the patients received CRT. The primary outcome of the trial was death from any cause. The secondary outcomes were sudden cardiac death and cardiovascular death. V体育安卓版.

Results: After a median follow-up period of 67. 6 months, the primary outcome had occurred in 120 patients (21. 6%) in the ICD group and in 131 patients (23. 4%) in the control group (hazard ratio, 0. 87; 95% confidence interval [CI], 0. 68 to 1. 12; P=0. 28). Sudden cardiac death occurred in 24 patients (4. 3%) in the ICD group and in 46 patients (8. 2%) in the control group (hazard ratio, 0. 50; 95% CI, 0. 31 to 0. 82; P=0. 005). Device infection occurred in 27 patients (4. 9%) in the ICD group and in 20 patients (3 V体育ios版. 6%) in the control group (P=0. 29). .

Conclusions: In this trial, prophylactic ICD implantation in patients with symptomatic systolic heart failure not caused by coronary artery disease was not associated with a significantly lower long-term rate of death from any cause than was usual clinical care. (Funded by Medtronic and others; DANISH ClinicalTrials. gov number, NCT00542945 . ). VSports最新版本.